?/td>
| TE2000-E |
TE2000-U |
TE2000-S |
Optical system |
CFI60 infinity optical system, parfocal distance 60mm |
?/td>
| Light distribution |
5 positions, motorized position changer |
Observation, left port, right port, front port, bottom port |
|
4 positions: |
Observation, left port, right port, front port |
*Model with bottom port also available as option. |
|
2 positions: |
Observation, left port |
*Model with right port instead of left port also available as option. |
|
Focusing |
Stroke—manual: up 7mm, down 3mm; motorized: up 6mm, down 2.5mm
Coarse stroke: 4.9mm/rotation; Fine stroke: 0.1mm/rotation (motorized)
Minimum fine reading: 0.05µm by optical linear encoder
External fine focus unit |
Stroke—manual: up 7mm, down 3mm
Coarse stroke: 4.9mm/rotation; Fine stroke: 0.1mm/rotation
Minimum fine reading: 1µm
Refocusing stopper: Adjustable coarse torque stopper |
Stroke—manual: up 7mm, down 3mm
Coarse stroke: 4.9mm/rotation; Fine stroke: 0.1mm/rotation
Minimum fine reading: 1µm
Adjustable coarse torque stopper |
Intermediate magnification |
1.5X |
1.5X |
— |
Other |
Light intensity control; Light on/off switch |
Eyepiece tube |
(1) |
T-TD Binocular Tube D |
(2) |
T-TS Binocular Tube S |
(3) |
T-TERG Binocular Ergonomic Tube D |
(4) |
T-TI Intermediate Tube for Eclipse E600/400 trinocular tubes and teaching heads |
|
Eyepiece lens |
CFI 10X (F.O.V. 22), CFI 12.5X (F.O.V. 16), CFI 15X (F.O.V. 14.5) |
Illumination |
(1) |
T-DH 100W Illumination Pillar |
(2) |
T-DS 30W Illumination Pillar |
|
Condenser |
SLWD condenser, ELWD condenser, System condenser LWD, ELWD Motorized system condenser LWD, ELWD, Hoffman Modulation condenser?
(HMC) W.D. 44mm, High NA condensers |
Revolving nosepiece |
Sextuple nosepiece, DIC sextuple nosepiece, Motorized DIC sextuple nosepiece |
Objectives |
CFI60 objectives |
Stage |
(1) |
T-SR Rectangular Stage—Cross travel: 70 x 50mm; Size: 300 x 276mm |
(2) |
T-SP Plain Stage—Size: 300 x 210mm; Mechanical stage mountable |
(3) |
T-SAM Attachable Mechanical Stage (must be used with T-SP Plain Stage)—Cross travel: 126 x 84mm; Specimen holders attachable |
|
Motorized functions |
Fine focusing (minimum reading: 0.05µm)
Objective anti-collision mechanism (when the nosepiece is rotated)
Light distribution changeover |
— |
— |
Options: DIC nosepiece, Analyzer, Epi-fl filter rotating turret, Epi-fl shutter, Excitation filter wheel,
Barrier filter wheel, System condenser turret |
Weight (approx.) |
Phase contrast set: 40kg; Epi-fl set: 45kg
(w/100W pillar) |
Phase contrast set: 36kg; Epi-fl set: 41kg
(w/100W pillar) |
Phase contrast set:
32kg (w/30W pillar) |